| 1 | +// SPDX-License-Identifier: GPL-2.0-only |
| 2 | +/* |
| 3 | + * PCIe cooling device |
| 4 | + * |
| 5 | + * Copyright (C) 2023-2024 Intel Corporation |
| 6 | + */ |
| 7 | + |
| 8 | +#include <linux/build_bug.h> |
| 9 | +#include <linux/cleanup.h> |
| 10 | +#include <linux/err.h> |
| 11 | +#include <linux/module.h> |
| 12 | +#include <linux/pci.h> |
| 13 | +#include <linux/pci-bwctrl.h> |
| 14 | +#include <linux/slab.h> |
| 15 | +#include <linux/sprintf.h> |
| 16 | +#include <linux/thermal.h> |
| 17 | + |
| 18 | +#define COOLING_DEV_TYPE_PREFIX "PCIe_Port_Link_Speed_" |
| 19 | + |
| 20 | +static int pcie_cooling_get_max_level(struct thermal_cooling_device *cdev, unsigned long *state) |
| 21 | +{ |
| 22 | + struct pci_dev *port = cdev->devdata; |
| 23 | + |
| 24 | + /* cooling state 0 is same as the maximum PCIe speed */ |
| 25 | + *state = port->subordinate->max_bus_speed - PCIE_SPEED_2_5GT; |
| 26 | + |
| 27 | + return 0; |
| 28 | +} |
| 29 | + |
| 30 | +static int pcie_cooling_get_cur_level(struct thermal_cooling_device *cdev, unsigned long *state) |
| 31 | +{ |
| 32 | + struct pci_dev *port = cdev->devdata; |
| 33 | + |
| 34 | + /* cooling state 0 is same as the maximum PCIe speed */ |
| 35 | + *state = cdev->max_state - (port->subordinate->cur_bus_speed - PCIE_SPEED_2_5GT); |
| 36 | + |
| 37 | + return 0; |
| 38 | +} |
| 39 | + |
| 40 | +static int pcie_cooling_set_cur_level(struct thermal_cooling_device *cdev, unsigned long state) |
| 41 | +{ |
| 42 | + struct pci_dev *port = cdev->devdata; |
| 43 | + enum pci_bus_speed speed; |
| 44 | + |
| 45 | + /* cooling state 0 is same as the maximum PCIe speed */ |
| 46 | + speed = (cdev->max_state - state) + PCIE_SPEED_2_5GT; |
| 47 | + |
| 48 | + return pcie_set_target_speed(port, speed, true); |
| 49 | +} |
| 50 | + |
| 51 | +static struct thermal_cooling_device_ops pcie_cooling_ops = { |
| 52 | + .get_max_state = pcie_cooling_get_max_level, |
| 53 | + .get_cur_state = pcie_cooling_get_cur_level, |
| 54 | + .set_cur_state = pcie_cooling_set_cur_level, |
| 55 | +}; |
| 56 | + |
| 57 | +struct thermal_cooling_device *pcie_cooling_device_register(struct pci_dev *port) |
| 58 | +{ |
| 59 | + char *name __free(kfree) = |
| 60 | + kasprintf(GFP_KERNEL, COOLING_DEV_TYPE_PREFIX "%s", pci_name(port)); |
| 61 | + if (!name) |
| 62 | + return ERR_PTR(-ENOMEM); |
| 63 | + |
| 64 | + return thermal_cooling_device_register(name, port, &pcie_cooling_ops); |
| 65 | +} |
| 66 | + |
| 67 | +void pcie_cooling_device_unregister(struct thermal_cooling_device *cdev) |
| 68 | +{ |
| 69 | + thermal_cooling_device_unregister(cdev); |
| 70 | +} |
| 71 | + |
| 72 | +/* For bus_speed <-> state arithmetic */ |
| 73 | +static_assert(PCIE_SPEED_2_5GT + 1 == PCIE_SPEED_5_0GT); |
| 74 | +static_assert(PCIE_SPEED_5_0GT + 1 == PCIE_SPEED_8_0GT); |
| 75 | +static_assert(PCIE_SPEED_8_0GT + 1 == PCIE_SPEED_16_0GT); |
| 76 | +static_assert(PCIE_SPEED_16_0GT + 1 == PCIE_SPEED_32_0GT); |
| 77 | +static_assert(PCIE_SPEED_32_0GT + 1 == PCIE_SPEED_64_0GT); |
| 78 | + |
| 79 | +MODULE_AUTHOR("Ilpo Järvinen <ilpo.jarvinen@linux.intel.com>"); |
| 80 | +MODULE_DESCRIPTION("PCIe cooling driver"); |
0 commit comments